LOA stands for Level of Accuracy. LOA is structured in five increments of ten beginning with LOA10 and extending thru LOA50. The five defined Levels of Accuracy are – LOA10, LOA20, LOA30, LOA40 and LOA50.
This specification prescribes five levels of accuracy for building documentation. Each of the five levels can be applied within the same project as the Level of Accuracy may be applied to the elements of the building documentation project and not necessarily to the project in totality.
| LOA Range
| |
Level | Upper range | Lower Range |
LOA10 | User Defined | 5cm * |
LOA20 | 5cm * | 15mm * |
LOA30 | 15mm * | 5mm * |
LOA40 | 5mm * | 1mm * |
LOA50 | 1mm * | 0* |
*Specified at the 95 percent confidence level.
📓Note
Option of setting LOA gets enabled when the LOD is set at 500 or 5 (depends on the setting).